Home Product range 0,6/1kV cables RZ1FAZ1-K (AS) 0,6/1kV
RZ1FAZ1-K (AS) 0,6/1kV Print E-mail

Description

RZ1FAZ1-K (AS) 0,6/1kV

 

rz1faz1-ksombra.jpg

 

 

Description


These cables are indicated for executing permanent installations where low fumes and corrosive gas emission is required in the event of fire, such as public premises, hospitals, schools, shopping centres and airports. The metal band provides greater protection against mechanical aggressions and the action of rodents. Their flexibility makes them very appropriate in complex and extremely difficult installations.

Applications


  • Underground supply networks for outdoor lighting installations


They can also be used in the following applications:

  • Underground networks for low voltage distribution
  • Electricity distribution networks. Underground service connections
  • Installations in premises with special characteristics



Appropriate for installations where greater fire protection is required.

industrial.gif

flexible.gif

90.gif

fortachon.gif

as.gif

Technical characteristics

RZ1FAZ1-K (AS) 0,6/1kV

 

 

 

rz1faz1-kconstruccion.jpg
rz1faz1-kdetalle.jpg

 

1. Conductor

Flexible electrolytic copper conductor(Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insulation

Cross-linked polyethylene insulation(XLPE), type DIX-3, according to UNE 21123 and HD 603S1

3. Armature seat

Thermoplastic polyolefin.

4. Metal armature

Metal armature, Aluminium band.

5. Sheathing

hermoplastic polyolefin sheath according to UNE 21123.

Rated volatge

0,6/1kV

Test voltage

3.500V in A.C.

Maximum temperature

90ºC

Other characterisics

  • Colours according to UNE 21089 and HD 303S2:2001
  • Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
  • Non-fire propagating according to UNE-EN 50266 and EN 50266
  • Low halogen content according to UNE-EN 50267 and EN 50267
  • Low corrosive gas emission according to UNE-EN 50267 and EN 50267
  • Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034

National norm / european

EN 60332-1 / EN 50266 / EN 50267-1 / EN 50267-2 / EN 61034
International norm
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034

 

Dimensions

RZ1FAZ1-K (AS) 0,6/1kV

 

Section

(mm2)

Resistance at 20ºC (Ω/km)

External Diameter (mm)

Weight (kg/Km)

1x6

3,30

11,98

229

1x10

1,91

13,00

286

1x16

1,21

13,90

353

1x25

0,780

14,70

452

1x35

0,554

16,00

567

1x50

0,386

17,90

733

1x70

0,272

19,60

952

1x95

0,206

21,90

1.182

1x120

0,161

23,40

1.456

1x150

0,129

25,30

1.779

1x185

0,106

28,20

2.088

1x240

0,0801

32,00

2.705

1x300

0,0641

34,20

3.289

 

Documents

RZ1FAZ1-K (AS) 0,6/1kV

 

 