Home Product range 0,6/1kV cables RZ1FZ1-K (AS) 0,6/1kV
RZ1FZ1-K (AS) 0,6/1kV Print E-mail

Description

RZ1FZ1-K (AS) 0.6/1kV

 

rz1fz1-k_webconsombra.jpg

 

Description


These cables are indicated for executing permanent installations where low smoke and corrosive gas emission is required, in the event of fire, such as public premises, hospitals, schools, shopping centres and airports. The metal band provides greater protection against mechanical aggressions and the action of rodents. Their flexibility makes them very appropriate in complex and extremely difficult installations.

Applications


  • Underground supply networks for outdoor lighting installations


They can also be used in the following applications:

  • Underground networks for low voltage distribution
  • Electricity distribution networks. Underground service connections
  • Installations in premises with special characteristics



Appropriate for installations where greater fire protection is required.

industrial.gif

flexible.gif

90.gif

fortachon.gif

as.gif

Technical characteristics

RZ1FZ1-K (AS) 0.6/1kV

 

rz1fz1construccion.jpg
rz1fz1detalle.jpg

 

1. Conductor

Flexible electrolytic copper conductor (Class V) according to BS EN 60228:2005 (previously BS6360) and UNE 60228.

2. Insulation

Cross-linked polyethylene insulation (XLPE), type DIX-3, according to UNE 21123 and HD 603S1

3. Armature Seat

Thermoplastic polyolefin

4. Metal armature

Metal armature, Aluminium band.

5. Sheathing

Thermoplastic polyolefin sheath according to UNE 21123.

Rated voltage

0,6/1kV

Test voltage

3.500V in A.C.

Maximum temperature

90ºC

Other characteristics

  • Colours according to UNE 21089 and HD 303S2:2001
  • Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332 Non-fire propagating according to UNE-EN 50266 and EN 50266
  • Low halogen content according to UNE-EN 50267 and EN 50267
  • Low corrosive gas emission according to UNE-EN 50267 and EN 50267
  • Low opaque smoke emission according to UNE-EN 61034, EN 61034 and IEC 61034
  • The use of cross-linked polyethylene (XLPE) admits greater current density, at equal section, respect to the insulation with PVC.

National norm / european

EN 60332-1 / EN 50266 / EN 50267-1 / EN 50267-2 / EN 61034
International norm
IEC 60332-1 / IEC 60332-3 / IEC 60754-1 / IEC 60754-2 / IEC 61034

 

Dimensions

RZ1FZ1-K (AS) 0.6/1kV

 

Section

(mm2)

Resistance at 20ºC (Ω/km)

External Diameter (mm)

Weight (kg/km)


Section

(mm2)

Resistance at 20ºC
(Ω/km)

External
Diameter
(mm)

Weight
(kg/km)

2x1,5

13,30

10,60

207


4x4

4,95

14,50

419

2x2,5

7,98

11,50

249


4x6

3,30

15,50

510

2x4

4,95

12,90

318


4x10

1,91

19,00

817

2x6

3,30

13,70

475


4x16

1,21

21,80

995

2x10

1,91

16,80

567


4x25

0,780

25,00

1.566

2x16

1,21

19,80

793


4x35

0,554

28,10

2.035

2x25

0,780

21,80

1.041


4x50

0,386

33,20

2.805

3x1,5

13,30

11,00

227


4x70

0,272

38,90

4.226

3x2,5

7,98

12,00

332


5x1,5

13,30

12,60

297

3x4

4,95

13,50

361


5x2,5

7,98

13,80

425

3x6

3,30

15,40

452


5x4

4,95

15,60

489

3x10

1,91

17,60

663


5x6

3,30

19,70

660

3x16

1,21

20,20

910


5x10

1,91

22,10

962

3x25

0,780

23,00

1.268


5x16

1,21

25,70

1.355

3x35

0,554

24,80

1.510


5x25

0,780

29,40

1.945

4x1,5

13,30

11,80

260


5x35

0,554

30,84

2.339

4x2,5

7,98

12,90

322


5x50

0,386

38,00

3.222

Cables with more than 3 conductors can be manufactured with one of the primaries yellow/green.


Documents

RZ1FZ1-K (AS) 0.6/1kV

 

 

pdflogo2.jpg