Description
Used for internal wiring of control equipment, in those places where special high temperature behaviour is required. Its standardisation, HD 21, BS 6231, UL 758 y CSA 22.2, makes it suitable to be marketed all over the world without technical barriers.
|
|
Applications
Internal or external wiring for electrical or electronic equipment.
- Installations in premises with special characteristics: premises at high temperature
|
|
1.Conductor
|
Electrolytic copper conductor, Class I, according to BS EN 60228:2005 (previously BS6360) and EN 60228. |
|
2.Insulation
|
PVC insulation, type TI-3, according to BS 6231, UL 758 and CSA 22.2, UNE 21031-7 and HD 21.7S2:1996/A1:1999. |
|
Rated voltage
|
450/750V; UL: 600V |
|
Test voltage
|
2.500V in A.C. |
|
Maximum temperature
|
105ºC |
|
Other characteristics
|
- Colours according to UNE 21031 and HD 21.1S4:2002
- Non-flame propagating according to UNE-EN 60332, EN 60332 and IEC 60332
- PVC insulation with reduced hydrogen chloride (HCL) emission.
|
|
National norm / european
|
EN 60332-1
|
|
International norm
|
IEC 60332-1 |
|
Style
|
AWG
|
Section (mm2)
|
Resistance at 20ºC (Ω/km)
|
External Diameter (mm)
|
Weight (kg/Km)
|
|
1015
|
16
|
1,5
|
12,10
|
2,90
|
20
|
|
1015
|
14
|
2,5
|
7,41
|
3,50
|
35
|
|
1015
|
12
|
4
|
4,61
|
4,00
|
45
|
|